Chicago brick oven CBO - 500 User Manual

Browse online or download User Manual for Fireplaces Chicago brick oven CBO - 500. CHICAGO BRICK OVEN 13-0388 CBO-500 3-18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
CHICAGO BRICK OVEN
13-0388
Clearance (Air Space) Diagram
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING
INSTRUCTIONS.
CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPEC-
TION IN YOUR AREA.
FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE.
USE ONLY WITH A LINED MASONRY OR LISTED TYPE HT FACTORY-BUILT CHIMNEY. FOLLOW INSTRUC-
TIONS FOR PASSING CHIMNEY THROUGH COMBUSTIBLE WALLS AND CEILINGS.
MAINTAIN 10" (254mm) CLEARANCE (AIR SPACE) ON ALL SIDES AND 18" (457.2mm) ON TOP AND
30"
(762mm) ON BOTTOM FROM COMBUSTIBLE MATERIALS. DO NOT FILL REQUIRED AIR SPACE WITH
INSULATION OR OTHER MATERIALS.
FACE OF ENCLOSURE MUST BE CONSTRUCTED OF A NON-COMBUSTIBLE MATERIAL.
FOR INDOOR APPLICATIONS: THIS COOKING EQUIPMENT MAY BE USED WITH AN EXHAUST HOOD TESTED
FOR COMPLIANCE WITH THE STANDARD FOR VENTILATION CONTROL AND FIRE PROTECTION OF
COMMERCIAL COOKING OPERATIONS, NFPA96, OR WITH THE REQUIREMENTS IN THE STANDARD FOR
EXHAUST HOODS FOR COMMERCIAL COOKING EQUIPMENT, UL 710. REFER TO HOOD MANUFACTURER’S
INSTALLATION INSTRUCTIONS FOR PRECAUTIONS
, CLEARANCES, AND MINIMUM REQUIRED AIR FLOWS
REQUIRED FOR INSTALLATION OF THE EXHAUST HOOD AND REFERENCE TO BUILDING CODES DETAILS.
OVEN SUPPLIED WITH THERMOWORKS IR-GUN-S INFRARED TEMPERATURE GUN.
TO REDUCE RISK OF CREOSOTE FIRE, INSPECT OVEN TWICE MONTHLY AND CLEAN WHEN NECESSARY.
DO NOT OVERFIRE; WHEN FLAME SPILLS OUT OF THE OVEN YOU ARE OVERFIRING. DO NOT USE GRATE OR
ELEVATE FIRE; BUILD FIRE DIRECTLY ON HEARTH. DO NOT OPERATE WITH OVEN DOOR CLOSED.
DO NOT REMOVE OR COVER THIS LABEL.
Conforms to: UL Subject 2162 & NSF/ANSI STD 4
Certified to: ULC STD S627
CAUTION: HOT WHILE IN OPERATION,
DO NOT TOUCH. KEEP CHILDREN, CLOTHING,
AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. SEE NAME PLATE AND
INSTRUCTIONS.
CHICAGO BRICK OVEN, LLC
205 E. BUTTERFIELD RD., #448
ELMHURST, IL 60126
REFRACTORY WOOD BURNING OVENS
CBO-500 CBO-750
40074334007432
Manufacturer’s Identification Number
MANUFACTURED
Aerial View
10"10"
10"
Front View
18"
30"
Page view 0
1

Summary of Contents

Page 1 - Clearance (Air Space) Diagram

CHICAGO BRICK OVEN13-0388Clearance (Air Space) DiagramINSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIO

Comments to this Manuals

No comments